SHIVAS Reinplast · Wire pretreatment lines

Fumeless pickling line

Turnkey line

Fumeless pickling lines: wire cleaned in covered tanks with no acid fume in the shed.

  • Drawing: Not in line or Inline drawing
  • Take-up: Coilers or Spoolers
Fumeless pickling line5 photos
Covered tanksfume stays inside
Multi-strandcontinuous
Low acidcontrolled baths

Overview

Fumeless pickling runs strands through covered tanks with controlled acid and temperature, so fume stays in the equipment and is drawn off to a small scrubber.

Tank lids and strand slots are designed so very little air enters, which keeps the extraction small. Acid strength, temperature and iron are held in a narrow band; rinsing is cascaded; the small scrubber stream can go to acid recovery.

Why it pays

Clean shed

No acid fume.

Lower acid use

Controlled baths.

Technical specification

Typical ranges. Every unit is sized to your duty; the offer carries the exact figures.

TanksCovered PP-H
StrandsMulti-strand
ExtractionSmall scrubber
Line drawing

Calculator

Work it out for your own plant. Every input is a typical value you can change and the results follow as you type; send the result to us and we reply with a proposal.

Every stage of the line

In order from the coil going in to the coil coming out. Watch it run in the wire lines section.

  1. Pay-off
  2. 1
    Rod pay-offsTechnology

    Overhead or rotating pay-offs feed hot-rolled rod. Butt welding joins each new coil to the last, so strands never need re-threading.

    Feed
    Hot-rolled rod coils
    Joining
    Butt welding
    Built by
    SHIVAS Technology
  3. Pretreatment
  4. 2
    Mechanical descalerTechnology

    Reverse-bending rolls crack the mill scale and brushes take it off. Most of the scale leaves dry, so the acid lasts much longer.

    Method
    Reverse bending + brushing
    Scale
    Collected dry
    Gain
    Less acid, less iron load
  5. 3
    Fumeless HCl picklingReinplast

    Two covered tanks in series. The rod meets the older acid first and the fresh acid last, while the acid cascades the other way, so it’s used up before it goes to regeneration. Lids, water seals and slot extraction keep the fume in the tank.

    Chemistry
    HCl 12–18 % + inhibitor
    Temperature
    Ambient to 35 °C
    Flow
    Counter-current cascade
    Build
    PP-H tanks, FRP lids, PP pumps
  6. 4
    High-pressure spray rinseReinplast

    Jets strip loose smut and acid from the rod surface before the rinse tanks.

    Nozzles
    High-pressure, ring headers
    Water
    Recirculated
    Build
    PP-H spray box
  7. 5
    Cascade rinseReinplast

    Two or three counter-flow stages with a spray at the exit. Clean water enters only at the last stage, so water use stays low and the overflow goes to the ETP.

    Stages
    2–3, counter-flow
    Overflow
    To ETP or acid make-up
    Build
    PP-H tanks, PP spray headers
  8. Coating
  9. 6
    Carrier coatingReinplast

    A zinc phosphate, borax or lime carrier holds the drawing soap in the die and protects the rod until it is drawn.

    Chemistry
    Zinc phosphate, borax or lime
    Temperature
    ≈ 60–90 °C
    Sludge
    Filter loop on the tank
    Build
    PP-H tank, PTFE heating
  10. Post-treatment
  11. 7
    DryerTechnology

    Hot air sets the coating so it doesn’t smear in the soap box.

    Temperature
    ≈ 120–180 °C
    Build
    Insulated box, hot-air blower
  12. Drawing
  13. 8
    Inline drawingTechnologyOption: Inline drawing

    A straight-line drawing machine in the line takes the clean, coated wire straight down to size, with no coil handling between pretreatment and drawing.

    Machine
    Straight-line, multi-block
    Lubricant
    Soap in rotating die boxes
    Cooling
    Water-cooled blocks
    Built by
    SHIVAS Technology
  14. Take-up
  15. 9
    CoilersTechnology

    A coiler for each strand, inverted vertical or dead block, building tight, heavy coils on carriers while the line keeps running.

    Package
    Coils on carriers
    Type
    Inverted vertical / dead block
    Drive
    AC inverter, PLC synced

Around the line

Options, build and uses

Options

  • Electrolytic cleaning

How we build it

  • Fabricated by SHIVAS Reinplast

Who it is for

  • Wire galvanizing and drawing plants

What this plant is built from

In process order. Each one has its own page.

Questions buyers ask

Truly no fume?

Fume is contained inside the covered tanks and extracted.

From our engineers

Practical notes from the engineers who design and build these plants.

All articles from our engineers →

Enquiry · Fumeless pickling line

Get a quote

Tell us the capacity, sizes and site. We reply with a scheme, a layout and an offer.

What we need for your quote

  • Strands, sizes, speed

Other full lines and plants

See all products →