Fume scrubber and blower calculator
Size a packed-bed fume scrubber from your tanks: the extraction air, tower diameter and packing height, recirculation pump, pressure drop, and the blower motor in kW and HP.
What you enter
- Fume, one of: HCl fume (pickling); H₂SO₄ mist; HF / HNO₃ / NOx (stainless pickling); Ammonia / flux fume; Chromic acid mist (plating)
- Tanks extracted, typical 3
- Tank length, typical 6 m
- Tank width, typical 1.2 m
Under Advanced, 7 more inputs for a closer answer, each set to a typical value until you change it: Capture rate 0.38 m³/s·m²; Extra air 0 m³/h; Tower air velocity 2 m/s; Removal wanted 95 %; Liquid / gas ratio 2.5 L/m³; Duct run 40 m; Fan efficiency 62 %.
What it works out
- Air flow
- Tower
- Blower motor
- Recirculation
- System pressure drop
- Transfer units needed
- Main duct at 12 m/s
- Scrubbing liquid
- Recommended blower
- HCl evaporated (≈ 50 g/m²·h)
How it works
Capture air from tank surface area × capture rate; packing height = transfer units × height of a transfer unit for random PP packing. Pressure drop scales with the square of tower velocity. SHIVAS Reinplast builds the hoods, ducts, scrubber, FRP blower and stack in PP / FRP.
Each size it picks (a motor, burner, rectifier or fan) is the next standard size above the calculated need. Choose an extra margin of 10, 20 or 30 % and it is added to the need before the size is picked; nothing else is added.
The answer is a first sizing from typical values, and every input can be changed. Press Ask our engineer to check this under the results and SHIVAS replies with a checked sizing and a proposal.
The equipment it sizes
The same calculator is on each of these pages.
- Fume scrubbers & extractionPacked-bed and spray scrubbers with lip or room extraction, FRP ducting and stacks for acid shops and process plants.
- MS & SS scrubbers and fume systemsMild steel and stainless steel scrubbers and fume systems for hot gases and dust.
- Air pollution control systemsAir pollution control systems: cyclones, bag filters and scrubbers combined for the full duty.
- Suction hoodsSuction hoods and lip extraction for tanks, capturing fume at the surface.
- Acid fume extractionAcid fume extraction: lip or room extraction over the acid tanks, scrubbed in a PP or FRP wet scrubber and moved by an FRP blower.
- Acid enclosed roomA closed pretreatment room with its own extraction and a crane slot, so acid fume stays away from steelwork, cranes and people.
From our engineers
- Acid fume from pickling: hoods, the packed scrubber and the blowerHydrochloric acid fume corrodes everything it touches, starting with the building. How a SHIVAS Reinplast system captures it at the tank and washes it out
- When the shed still smells of acid: troubleshooting a fume scrubberFume at the tanks, a sour smell and rusting steel from a scrubber that is installed but not working. Where to look, in order: capture, ducts, packing and fan.
- Fumeless pickling for wire: keeping the acid inside the tankContinuous wire lines can pickle without filling the shed with acid fume. How covered, controlled tanks change the economics.
Other calculators
- Galvanizing plant calculatorKettle, furnace, zinc, fuel and cost per tonne from your steel and tonnage.
- Electro-galvanizing rectifierCurrent, current density and rectifier size
- Wire drawingPasses, die sequence, block speeds, kW and output
- High-velocity burner kWFiring rate, burners, wall heat flux, fuel
- ETP and ZLD plantNeutraliser, sludge, RO, MEE or MVR, ATFD, steam and power
- Coating thickness checkISO 1461 minimums, g/m², zinc per tonne
- Inline phosphating lineBath length, coating time, phosphate and output
- Pickling acidAcid use, spent acid, tank charge
- Spent acid neutralisationLime, filter cake and dissolved salt
- Bag filterCloth area, bags, housing, fan kW and HP
- Fan / blower motorAir power, shaft kW, motor kW and HP
- FRP profile weight and deflectionkg per metre, steel comparison, beam check